+86 132 2906 5196

Single Core Stranded bare copper PVC Insulated Cable

Applications

The H05V-R and H07V-R cables are color-coded PVC sheathed, copper single-core stranded wires. Specially suitable for application in:

  Dry protected installations including light fittings,switch and distribution boards

  Laid inside conduit and trunking, under plaster

  on cable trays and cable supports

 

 For any more information or advice please contact the office on 0086-13229065196(WhatsApp/WeChat)


Share:

Details

PVC Insulated Flexible Cable

These cables are preferably for installation indoors, in cable ducts and in industrial plants or switching stations, under ground installation, can be used in switchboards and distributor boards or where a thicker strand of multi-wire is required. 

Construction

Single Core Stranded bare copper PVC Insulated Cable

Description:  H05V-R &H07V-R, PVC Insulated Copper Cable   

Conductors:  Class2 of plain annealed stranded copper  

Insulation:  Polyvinyl chloride PVC

Colour of Sheath:  Any Colour

Voltage Rating (Uo/U)  H05V-R: 300/500V  H07V-R:450/750V  

Test Voltage    H05V-R: 2kV for 5 minutes   H07V-R: 2.5kV for 5 minutes

Physical Properties

Maximal operating conductor Temperature: up to 70℃(PVC insulation); up to 90(XLPE insulation)

Operating Temperature Range: -5℃(PVC or LSZH sheath); -20℃(PE sheath)

Short Circuit Temperature(5 seconds maximum duration): 140-160℃(PVC insulation);250℃(XLPE insulation)

Technical Data

                                                         300/500V  H05V-R Stranded bare copper (IEC60228Cl-2) PVC Insulated cable
No. of cores and nominal cross sectionThickness of InsulationApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)
(mm2)(mm)(mm)(kg/km)(Ω/km)
1 X 0.50.6 2.1 936.0 
1 X 0.750.6 2.3 1224.5 
1 X 10.6 2.5 1418.1 
                                              450/750V  H07V-R stranded bare copper (IEC60228Cl-2) PVC Insulated cable
No. of cores and nominal cross sectionThickness of InsulationApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)
(mm2)(mm)(mm)(kg/km)(Ω/km)
1 X 1.50.7 3.0 2112.1 
1 X 2.50.8 3.6 327.41
1 X 40.8 4.2 474.61
1 X 60.8 4.8 663.08
1 X 101.0 6.5 1121.83
1 X 161.0 7.5 1681.15 
1 X 251.2 9.5 2640.727
1 X 351.2 10.6 3540.524
1 X 501.412.4 4800.387
1 X 701.414.36800.268
1 X 951.616.79370.193 
1 X 1201.618.611760.153
1 X 1501.820.414470.124
1 X 1852.0 22.918190.0991
1 X 2402.226.723860.0754
1 X 3002.430.530190.0601
1 X 4002.633.938043047